Free tool · PinningLab
SFIC A2 pinning calculator
Enter up to three operating keys and the control key, seven cuts each. For every chamber the lowest operating cut is the bottom pin, the steps between operating cuts are master pins, the build-up reaches the control level (control cut + 10), and the top pin brings the stack to 23. The Schlage Everest 29 SL Service Manual 111232 Rev. 01/22 example is filled in.
PinningLab: Locksmith Charts
SFIC A2 and master-keyed pinning charts
PinningLab: Locksmith Charts is for iPhone and iPad; there is no Android version.
Free to download for iPhone and iPad.

Seven cuts per key, 0–9, first chamber first (spaces are fine). Use only bittings you already have for a core you are authorized to service. Nothing you enter leaves your browser.
| Chamber | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
|---|---|---|---|---|---|---|---|
| Top | 9 | 12 | 10 | 11 | 8 | 10 | 12 |
| Build-up | 6 | 2 | 4 | 8 | 10 | 10 | 4 |
| Master | 6 | 8 | 2 | 4 | 2 | 2 | 6 |
| Bottom | 2 | 1 | 7 | 0 | 3 | 1 | 1 |
| Total | 23 | 23 | 23 | 23 | 23 | 23 | 23 |
Control shear line at 14, 11, 13, 12, 15, 13, 11; every stack totals 23.
Pins for this core
- Bottom 0 × 1
- Bottom 1 × 3
- Bottom 2 × 1
- Bottom 3 × 1
- Bottom 7 × 1
- Build-up 2 × 1
- Build-up 4 × 2
- Build-up 6 × 1
- Build-up 8 × 1
- Build-up 10 × 2
- Master 2 × 3
- Master 4 × 1
- Master 6 × 2
- Master 8 × 1
- Top 8 × 1
- Top 9 × 1
- Top 10 × 2
- Top 11 × 1
- Top 12 × 2
PinningLab: Locksmith Charts saves this chart with the job, flags a cut outside the depth range or the MACS limit at the exact chamber, and exports a PDF or CSV worksheet, redacted if you like.
PinningLab: Locksmith Charts is for iPhone and iPad; there is no Android version.



Everything in the app
- SFIC A2 pinning with control shear line, build-up pins and the total-stack rule
- Master-keyed charts with any number of operating keys, validated at the exact chamber
- Pin-stack diagrams, the full pin tally and PDF or CSV job worksheets
- Encrypted job history with Face ID
- Each bundled profile cites its manufacturer
How an A2 stack is built
A small format interchangeable core has two shear lines. The operating keys turn the plug at the operating shear line; the control key lifts the stack to a second line, the control shear line, so the core can be removed. In the A2 system each depth step is one increment, the control shear line sits 10 increments above the operating one, and every chamber’s pins add up to the same 23 increments.
So for each chamber, take the cuts of every operating key and sort them. The lowest is the bottom pin. Each step up to the next operating cut is a master pin. The control level is the control key’s cut plus 10, and the build-up pin is the distance from the highest operating cut to that level. Whatever is left of the 23 is the top pin. Chamber 1 of the example has operating cuts 2 and 8 and a control cut of 4: bottom 2, master 6, build-up 6 (14 − 8), top 9 (23 − 14).
The published example, and its one misprint
The calculator opens on the worked example in the Schlage Everest 29 SL Service Manual 111232 Rev. 01/22, page 18: a top master of 2974531, a change key of 8190317 and a control key of 4132531. Chambers 1 to 6 match the printed chart exactly. In chamber 7 the printed build-up pin is 5, but the document’s own rule gives 4: a control level of 1 + 10 = 11 minus the highest operating cut 7. A 5 would make that stack 24, not 23, and could not produce the top pin of 12 printed in the same column. PinningLab records this as a source erratum, shows it in the profile details and applies the rule. Whichever value you trust, check it against a physical core before loading.
For this core the set adds up to 28 pins, listed by role and size under the chart, which is the count to pull from the kit before you start.
What to check before loading
- The system. These constants are A2 only. Other SFIC systems and conventional cylinders use other offsets and stack rules; never apply A2 numbers to them.
- Every cut. Compare each entered bitting with the job record, first chamber first.
- Your pin kit. Make sure every size in the tally exists in the kit you will use; a missing size is not something to round.
- Adjacent cuts. The manual states no MACS for A2; check adjacent-cut limits against your own key system.
PinningLab runs these checks for you on every job and stops at the chamber that fails, for A2 and for conventional master-keyed cylinders.
Questions people ask
How do you calculate SFIC A2 build-up pins?
Add 10 to the control key’s cut to get the control level, then subtract the highest operating cut in that chamber. In chamber 1 of the Schlage Everest 29 SL Service Manual 111232 Rev. 01/22 example, the control cut is 4, so the control level is 14; the highest operating cut is 8, so the build-up pin is 6.
Why does every A2 chamber add up to 23?
The A2 system uses a fixed stack height: bottom, master, build-up and top pins together always measure 23 increments. The top pin is whatever brings the stack to 23 after the control level.
Is the chamber 7 build-up in the Schlage example 4 or 5?
By the document’s own rule it is 4: the control cut 1 plus 10 is 11, and 11 minus the highest operating cut 7 is 4. The printed chart shows 5, which would make that stack 24 and contradict the same figure’s top pin of 12. PinningLab and this calculator apply the rule; verify against a physical core before loading.
Do I need a master pin in every chamber?
Only where the operating keys differ. If every operating key has the same cut in a chamber, there is no master pin there. A single change key with cut 3 and a control cut of 4 gives a bottom pin of 3, a build-up of 11 and a top pin of 9.
Can this calculator decode a core or make a key system?
No. It calculates pins from bittings you already have for a core you are authorized to service. It does not decode keys, generate key combinations or master-key systems, or teach bypass techniques.